中广核地下室人防工程监理实施细则.doc
《中广核地下室人防工程监理实施细则.doc》由会员分享,可在线阅读,更多相关《中广核地下室人防工程监理实施细则.doc(25页珍藏版)》请在咨信网上搜索。
上海中广核技术产业研发中心工程 监理施行细那么 〔地下室人防工程〕 专业监理工程师: 总监理工程师: 上海申海建立监理 中广核技术产业研发中心工程监理部 2021年8月 目 录 一、工程概况····················································································································3 二、〔人防区域〕设计要求·······························································································3 三、监理根据···················································································································4 四、监理目的····················································································································4 五、监理准备工作············································································································5 六、监理工作流程············································································································5 七、施工难点及监理重点······························································································11 八、监理预控要点··········································································································12 九、监理工作、措施及工程控制要点·································································12 一、工程概况 1.工程名称:上海中广核技术产业研发中心 2.子工程名称:包括地下室、产业中心、研发中心、图文中心、行政中心、会议中心、效劳中心、门卫8个子工程 3.参建: 建立:上海中广核工程科技 设计:同济大学建筑设计研究院〔集团〕; 监理:上海申海建立监理 施工:广厦建立集团有限责任 4.工程:上海闵行区紫竹科学园区东川路南、淡水河东、紫星路北吴泾镇工—52地块 5.建筑面积:总建筑面积109832m2其中地下室建筑面积32112m2〔人防防护单元建筑面积2000m2〕建筑基底面积18595 m2 6.建筑层数:地下一层、地上4及5层建筑度24m 7.构造性质:抗震设防烈度7度、设计使用年限50年、平安等级二级 二、〔人防区域〕设计要求 1.人防区域:①~⑧/~轴内设置人防地下室建筑面积2000m2地下室顶板室外部分覆土厚度450mm。 2.人防等级:甲类、核武器抗力级别6级、常规武器抗力级别6级防化等级丙级防水等级二级。 3.防护单元:防护单元建筑面积2000m2人防使用面积1900 m2、掩护面积1400 m2掩护人数1400人。 4.出入口:三个出入口战时主要出入口利用室外汽车坡道设置;战时次要出入口利用人防地下室东北侧楼梯人防区西侧设置一个战时人员疏散口 5.进、排风口:排风口设防爆波活门扩散室采用超压排风方式;进风口设进风竖井防爆波活门、扩散室、除尘滤室和进风机房。 6.人防与非人防部分平时出入口临战封堵:共计封堵4处:钢筋砼预制梁临战封堵2处、闭通道1处〔不计入临战转换工作量〕、钢筋砼防护闭门临战封堵1处。 7.地下室防水等级为二级抗渗等级P6。 三、监理根据 1人防根底构造设计图纸以及有关图纸会审纪要、设计变更、技术核定单等。 2.工程、合同及补充协议。 3.上级及颁发的施工、规定。 4.及上海施工、验收主要包括: ①?混凝土构造工程施工质量验收? GB50204-2002 ②?钢筋焊接及验收? JGJ18—96 ③?建筑工程施工质量验收统一? GB50300-2001 ④?混凝土构造施工图平面整体表示制图规那么和构造详图? 03G101-1 ⑤?地下防水工程质量验收? GB50208-2002 ⑥?人民防空工程质量检验评定? RFJ 01—2002 5.人防图集 DBJT08-10-79 97沪防-561、562 6.经审批的施工组织设计、施工方案等。 四、监理目的 1.质量目的:一次验收合格。 2.进度目的:在合同工内开工。 3平安监理目的:无重大平安事故和线事故争创级文明工地。 五、监理准备工作 1.人防地下室施工前监理组向提供资源装备申请包括与本工程相配套人员、检测设备、、图集等。 2.监理组熟悉施工图纸及相应的人防等。 3.编写人防监理细那么并进展交底。 4.总监组织监理组进展人防监理专业知识学习。 5.检查施工设备、材料、人员准备情况是否按既定的施工方案准备。 六、监理工作流程 1.施工组织设计〔方案〕审批程序 修改补充 提出修改 施工组织设计申报 承包 初 审 各专业监理工程师 向施工询问和落实主要问题 各专业监理工程师 监理组会审 工程总监主持各专业监理工程师参加 施工组织设计审批 工程总监 将批件返回承包并送业主 施工组织设计付诸施行 催促承包进展质量平安技术交底 2.分包商资格审查程序 总包提供合格分供商 监理工程师审查分包工程的申请: a.分包的资质证明; b.分包工程工程及内容; c.分包工程数量及金额。 总监理工程师 审批 承包商、分包方签订 工程分包合同 分包方进入工地施工 必要时进展实地考察 不 同意 3.施工图纸设计交底程序 布置图纸设计交底工作 总监理工程师 总监主持由业主、设计、施工、监理四方参加施工图纸设计交底 整理图纸各专业工种问题 熟悉施工图纸多提出问题 各专业监理工程师 监理会审 与业主、设计磋商落实中问题处理并整理归档 4.人防根底工程质量控制流程 合格 不合格 存在问题 合格 不合格 存在问题 不合格 复查轴线及标高 监理工程师 复查结果 返工 承包人 地基处理施工 填报地基处理质量验收签证 承包人 监理师发出口头或书面指 整改 承包人根据设计和要求自检合格并报有关资料 现场检查 现场监理工程师 现场抽样检查 专业监理工程师 检查结果 返工 承包人 监理工程师签字 根底施工 填报根底工程质量验收签证 承包人 现场检查 现场监理工程师 现场抽样检查 专业监理工程师 检查结果 承包人根据设计和要求自检合格并报有关资料 返工 承包人 总监理工程师签字 监理师发出口头和书面指 整改 5.钢筋混凝土工程质量控制流程 合格 不合格 合格 不合格 验收轴线、标高 监理工程师 钢筋工程自检合格 承包人 钢筋工程隐蔽验收 监理工程师 验收结果 模板工程自检合格 承包人 模板工程验收 监理工程师 验收结果 整改 承包人 验收 承包人 检查浇筑前的准备工作 监理工程师、承包人 签署混凝土浇筑 监理工程师 混凝土浇筑 承包人 6.材料审批程序 材料及设备进场前 填写“材料及设备进场报审表〞 承包方 提交材料有关如质保书、合格证、准用证、进沪答应证、商检等 承包方 审核 监理工程师 不准进场 材料进入施工现场 按规定批量自检填写 材料报审表 承包方 审核检查 监理工程师 进场使用 监理归档 监理抽检 制止使用 自费运出现场 监理按抽样检验频率和现场发现材料有问题时进展抽检 7.隐蔽工程验收程序 进展下一道工序施工 隐蔽工程施工完成 承包方 签署隐蔽工程验收单 监理工程师 隐蔽工程自检合格 承包方 填写隐蔽工程报验单 承包方 对所报隐蔽工程 检查验收 监理工程师 整改 承包方 七、施工难点及监理重点 人防工程与普通民用建筑不同在施工中往往忽略他们的差而产生质量通病这是本工程监理的重点亦是本工程的难点。监理将对以下方面予以重点控制: 1.土建部分: ·底板为梁板式梁板顶标高一致板的钢筋在梁主筋下。 ·墙模板的支设要求用有止水片的穿墙螺杆支模。 ·有槛临战封堵处要有角钢护角。 ·有槛门要有T型角钢护角。 2.安装部分: ·防爆波阀门专用防爆波阀门。 ·套为3~5mm钢板机械卷制不能用无缝钢。 ·人防地下室构造施工完成后要在回填土施工后〔穿墙螺杆不要进展处理〕请人防质检站验收合格方能进展装修施工。 八、监理预控要点 1.加强对施工资质审查要求承建建立健全质量保证体系并确保其有效的运转。 2.监理人员认真熟悉施工图理解工程特点〔特别是按照人防图集对照〕、工程关键部位的施工、质量要求;并对图纸中存在的问题通过建立向设计提出和建议。 3.监理人员参加设计技术交底会对图纸存在的问题和难以施工部位和设计人员讨详细施行方案。 4.组织监理组对施工报审的施工方案进展系统的审核。 5.严格对进场的原材料进展质量控制。 6.及时派测量监理师对本工程定位放线进展复合。 九、监理工作的、措施及过程控制要点 1.原材料的控制 ①钢筋:进场钢筋必须有出厂质量证明书和实验单按炉罐和直径分别检查钢筋标志和外观质量符合后〔每60吨为一取样〕随机取样送样;合格前方可使用。 ②水泥:进场水泥必须具有消费答应证、质量证明书〔同厂消费的水泥一个编为一个取样〕进展取样、送样合格前方可使用。 ③混凝土:本工程采用商品混凝土混凝土到场要有配合比;在混凝土浇筑地点随机抽取〔不超过200立方米同配合比混凝土〕取样不得少于一次。混凝土坍落度要符合施工要求。 ④砂浆:每天砌体中各种强度等级砂浆采用重量配合比并进展取样不得少于一次。 ⑤骨料〔砂、石〕进场要有出厂合格证;〔同产地、同规格以400立方米、600t为一取样〕取样、送样;合格前方可使用。 ⑥砌体:进场要有出厂合格证;〔对不同规格按照见证、取样手册所规定数量为一取样〕随机取样、送样;合格前方可使用。 ⑦防水卷材及防水涂料按进展取样、送检合格前方可使用。 ⑧须有进沪证的必须有“上海准用证〞。 ⑨人防工程专用设备必须由人防部门认可的专业消费工厂消费的合格。 2.人防钢筋混凝土地下室的控制 A、钢筋工程的质量控制 ①检查钢筋标牌、炉、厂家及出厂质量合格证、实验并按规定要求施工现场进展复试。 ②试验不合格的钢筋不能用于工程上并及时有关上级和监理工程师做处理并记录在案。 ③钢筋加工制作: ·施工应熟悉图纸向监理工程师提供加工方案加工翻样加工料表准备工作情况; ·操作人员必须实行挂牌制焊工持证上岗; ·钢筋的级别、钢和直径必须符合设计要求带有颗粒状或鳞片状老化锈蚀的钢筋不能用需要代换钢筋时必须上报监理工程师应征得设计的同意否那么不得以其他钢筋代换; ·加强钢筋翻样的控制。 ④钢筋加工成品要求: ·钢筋的形状、尺寸必须符合图纸要求; ·钢筋的外表应干净、无损伤、油漆和锈蚀; ·钢筋应平直无曲折外表不得有明显的擦伤; ·钢筋的弯折与弯钩应符合设计及要求; B、底板钢筋的检查 ①底板工程的关键部位及节点: ·口部防护闭门、闭门、防爆活门下槛梁绑扎; ·临空墙、闭墙、防护单元隔墙的插筋〔位置、弯锚朝向应正确〕; ·连通口、通风竖井处钢筋插筋; ·车道口部、防护单元隔墙处临战封堵下槛钢筋绑扎; ·外墙转角、丁字墙交接处定位插筋; ·墙底板、附墙柱施工缝处钢板止水带处墙板程度筋的构造处理; ②各个口部闭门〔即第二道门〕两侧的尺寸应注意即门轴侧宽度≥350mm另一侧为≥150mm否那么门扇安装后难以开启到位。 ③各个口部防护闭门〔即第一道门〕两侧箍筋为闭口箍闭门即第二道门两侧可按墙板程度筋绑扎。 ④楼梯间处的防护闭门假如侧向设置其侧面应设置附墙抗爆柱或抗爆梁出墙面≥100mm宽200~250mm或门框墙体缩进100mm。 ⑤所有墙板程度筋在端部均应制弯锚不得使用直条筋弯锚长度≥10d。 ⑥三防门下槛梁假如在底板混凝土浇捣后如发现箍筋偏低混凝土保护层增大均应进展调整采用开口箍与原有箍筋焊接并将下槛梁程度筋重新移至上层绑扎。焊接缝长度10d要求焊缝饱满并须敲掉焊渣。 ⑦进展临战封堵的竖向及上部角框焊制时要求角框垂直、平整焊缝饱满敲掉焊渣。竖向角须压在下部角框上焊接两角平直、对齐。角框反面应按设计要求焊接锚筋。锚筋采用Ⅰ级钢须做锚钩采用Ⅱ钢锚固长度均应到达30d。 ⑧如防护闭门、闭门设计为有槛门可在底板混凝土浇捣后在墙板钢筋绑扎后即进展角框安装要求角框面与混凝土构造面平、齐。 ⑨在进展墙板、柱钢筋绑扎前应首先按照控制标高进展测量作出程度标高控制点进展各项门框、安装预埋、构造标高控制。 在进展三防门门框墙钢筋绑扎是时应先将门框钢筋绑扎好然后安装三防门门框再绑扎门框上部墙板梁。只有再门框上部墙板梁钢筋绑扎完成后才能进展电气预埋。 三防门角框安装后进展各个面垂直调整并采用钢支架将门框支撑结实严禁将角框与门框墙钢筋焊接在一起。 在进展三防门门框安装时应检查门框位置的正确与否门轴侧边应≥350mm另一面≥150mm否那么门扇安装后难以开启到位。 临空墙、防护单元隔墙如有预留洞应设置双面角铁框角铁均应≥80mm一般为100mm。 防护单元隔墙的背靠三防护门均为防护闭门其钢筋断面一般为450mm。各个三防门门框在安装后才能绑扎门洞上部过梁板钢筋才能进展电气安装因此必须作好施工安排。另外在三防门门框安装好后所有门框墙钢筋均须重新进展整理这是必须进展的一道工序。 绑扎防爆活门钢筋应注意断面尺寸一般断面为≥450mm。 进展顶板隐蔽工程检查中勿忘三防门吊装的检查吊钩规格、形状、安装位置按施工土和检查。 口部工程的隐蔽工程检查中勿忘侧压的检查。 墙顶板交角处节点钢筋的绑扎应结实、平直。外墙外侧竖筋上部弯锚筋应捋须平直并与顶板筋绑扎。 应注意检查墙板、顶板下部混凝土垫块埔设混凝土严禁露筋。 外墙转角、丁字墙交接处点钢筋绑扎应按施工图和规定检查。 墙板拉结筋布置应梅花形排列勾住外层钢筋。 临战封堵除了预埋角框安装外其余设计图纸所标的封堵钢板等暂不施工临战前施工。 墙板预留孔及预埋处的构造钢筋设置应按施工图和进展检查。 连通口处后封堵混凝土可按一次性浇捣处理配置双面Ф8、200*200网片。 各个三防门侧安装的4根战时穿线应要求标高、位置一致竖向摆放应垂直连通口处可横放要求平直。 C、钢筋焊接接头的质量要求: ①焊工必须经过培训合格前方能上岗; ②批量钢筋焊接前必须根据施工条件试焊合格前方能大批量焊接; ③钢筋焊接质量按要求施工。 ④钢筋焊接加强加工前检查和加工中间检查焊接不合格的钢筋不能进入安装现场。 D、钢筋绑扎与安装: ①钢筋绑扎前要求弹出位置线标记分出双层钢筋位置线尤其是梁柱、防护隔墙、临空墙、主筋位置必须准确采取防位移措施; ②钢筋接头位置要符合施工验收和设计要求; ③检验质量按GB 50204-2002混凝土构造施工质量验收第五节钢筋分项工程和人民防空工程质量检验评定的有关规定。 E、混凝土工程和防水混凝土工程: ①混凝土开盘前的质量控制 ·检查搅拌后台的计量控制是否符合要求使用商品混凝土的必须对搅拌站的资质及质量保证体系进展审查; ·混凝土浇筑前施工必须向监理工程师提交原材料的材质证明和试验(包括商品混凝土)水泥应有出厂日出厂合格证、水泥强度、防渗等级、安定性试验砂石的试验和已通过试配的混凝土配比单。 ·混凝土浇筑前认真组织水暖卫、电气、土建结合检查办好隐蔽验收申报施工方案报监理工程师审核、检查批准后方能开场浇筑。 ②监理工程师在浇筑过程中进展跟踪检查对混凝土进展随机抽查发现缺陷及时处理。 ③配合比的控料 混凝土配合比的计算和试验应符合?普通混凝土配合比设计技术规定?按试配结果由实验室负责人签发配比单; ④商品混凝土搅拌、运输、泵送质量控制 ⑤施工现场混凝土质量理 现场必须具备混凝土试块的制作、养护条件有健全的理制度; ·现场试验员必须经培训、考核、持证上岗; ·混凝土施工前应作技术、平安交底并应具备混凝土养护条件特别是季节性施工间的防水、防冻措施要设专人负责施行; ·混凝土搅拌、运送、浇筑等过程中任何人不得擅自加水。 F、孔口防护工程的控制 ①孔口防护工程的质量监理程序 空口防护设备或预埋制作报监理审核 孔口防护工程测量轴线、标高报监理审核 监理检查、复验 钢筋绑扎预埋件、监理巡视 施工自检查 监理隐蔽工程验收 模板工程施工自检 监理检查 混凝土工程监理旁站 不合格 不合格 发 发 不合格 发 不合格 合格 发 序 防护设备名称 型 门洞〔宽×高〕mm〔B×H〕 门外通道最小宽度〔mm〕F 门外通道最小净高〔mm〕F 门扇最小开启宽度〔mm〕L 较页侧门框最小宽度〔mm〕D 门扇材料型式 门坎高度〔mm〕C 门扇质量〔单扇〕〔kg〕 吊环直径mm 1 闭门 M716 700×1600 1200 2000 1050 350 钢筋混凝土平板 ≥150 12 2 M820 800×2000 1300 2400 1150 350 钢筋混凝土平板 150 16 3 M1020 1000×2000 1500 2400 1400 350 钢筋混凝土平板 150 16 4 M1320 1300×2000 1800 2400 1700 350 钢筋混凝土平板 150 20 5 M1520 1500×2000 2000 2400 1900 350 钢筋混凝土平板 150 20 ②人防工程常用闭门基相应门框尺寸 G、施工过程控制 ①在主体工程钢筋绑扎间对孔口的防护闭门、闭门的位置、尺寸进展仔细测量放样。 ②门框墙施工应严格按照施工图图纸施工并符合以下要求: ·防护闭门门框墙及截面厚度的尺寸不小于300mm。 ·两个防护单元间的门框及门槛截面厚度不小于500mm。 ·门框墙的受力钢筋直径不应小于12mm间距不大于250mm配筋率不小于0.25。 ·门洞四角的内外侧应配置两根直径16mm斜向钢筋其长度不应小于1000mm。 ·防护闭门、闭门的钢制门框与门框墙之间有足够的连接强度并应浇捣实互相连成整体。 ③防护闭门、闭门门窗配筋严格按照设计要求并注意门的开启方向防止门框左右侧配筋位置过失如设计无门框墙的详细配筋图应参考有关人防工程图集。 ④有门框的门槛钢筋高出底板的高度应满足各种型的防护闭门和闭门门槛建筑高度。 ⑤防护闭门和闭门合页侧的门框最小宽度应满足人防门的安装尺寸闭锁侧的门框最小宽度应不会影响门扇的开启。 ⑥防护闭门和闭门的门框角钢预埋位置方向应准确防护闭门的角钢应预埋在非人防区一侧闭门的角钢宜预埋在染区一侧滤间的闭门角钢应预埋在闭通道内角钢的闭锁盒开口大头在下小头在上门轴位置与设计施工图一致。 ⑦预埋防护闭门和闭门的门扇吊钩应钩住顶板上层钢筋吊钩应放置在门扇宽度的以门轴圆心转45°角处其中FM25、FM〔M〕716的吊钩规格为Ф12FM818、FM〔M〕820、FM〔M〕1020的吊钩钩规格为Ф16FM〔M〕1320、FM〔M〕1520的吊钩规格为Ф20。 ⑧门框墙的混凝土浇筑应符合以下要求: ·门框墙应连续浇筑、振捣实、外表平整光滑无蜂窝、无孔洞。 ·门扇混凝土碎石粒径不应大于25mm且不应大于受力钢筋最小净距的3/4。 ·预埋铁件应除锈其安装的位‰置应准确固定应牢靠门框墙上应有预留电揽孔预埋孔洞应涂油或塞。 ⑨防护闭门、闭门的供给商必须是人防部门认可的专业消费消费报监理审核。 门扇安装应符合以下要求: ·钢门框支撑面的平整度不应超过1mm每边不平整部分累计的长度不应大于该边长度的20且应分布在2处以上;门框四边垂直度偏向不应超过长边的2‰。 ·门扇钢框与钢门框应贴合均匀其间隙不得大于2mm;每边不贴合部分累计的长度不应大于该边长度的20且应分布在2处以上。 ·铰页、闭锁安装位置应准确;上、下铰页同轴度偏向不应超过两铰页间距的1‰且不得大于2mm。 ·双扇拱形防护门的上、下两断与门框之间均应有50mm的间隙。 ·门扇应启闭灵敏。 ·在门扇外外表应标识闭锁开关方向。 封条安装应符合以下要求: ·封条接头应采用45°坡口搭接每扇门的封条接头不得超过2处。 ·封条应固定牢靠压缩均匀;部分压缩量允许偏向不应超过设计压缩量的20。 ·封条不得涂抹油漆。 孔口防护设施的包装应符合以下要求: ·各类防护设施均应具有出厂合格证。 ·防护设施的零、部件必须齐全井不得锈蚀和损坏。 ·防护设施分部件包装时应注明配套型、名称和数量。 门扇、门框的运输应符合以下要求: ·门扇混凝土强度到达设计要求后方可运输。 ·门窗和钢框应与车身固定牢靠。 防护设施的堆放应符合以下规定。 ·堆放场地应平整、巩固、无积水; ·金属构件不得露天堆放; ·各种防护设施应分类堆放; ·闭门及钢框应立式堆放; ·门窗程度堆放时其内外表应朝下;应在两长边放置同规格的条形垫木;在门框的跨中处不得放置垫木。 H、监理重点 ①检查钢筋、水泥、粗细骨料以及防护闭门、闭门、材料、设备得质量证书、准用证、消费答应证及有关试验。 ②在门框墙定位放样时监理人员仔细核对尺寸重点对门框墙门前尺寸、开启方向的位置尺寸仔细核对。 ③对防护闭门、闭门框的钢筋工程的隐蔽工程进展检查验收重点检查钢筋骨架的尺寸、钢筋直径、间距、垂直度以及预埋件、件的位置、方向等均应符合设计要求或有关人防图集。 ④钢筋配筋时检查门槛的钢筋高度是否符合各种型式门的建筑高度核对各种型式的门合页侧和闭锁侧的门框宽度能否满足开启的需要。 ⑤门框墙的混凝土浇筑时监理人员旁站催促施工连续浇筑和振捣实。 ⑥防护闭门、闭门安装前检查各扇门的平整度和在运输贮存过程中的受损如有损坏影响闭门等使用功能的应制止安装。 ⑦门窗安装时要求门扇钢框与钢门框贴合均匀其不贴部分和间隙都应符合要求。检查上、下铰页同轴度的偏向。 ⑧检查闭封条安装质量、闭条接头搭接形式、固定结实程度、压缩均匀程度均应符合要求。 ⑨进、出线的防护闭工程的质量监控: 进、出线的防护闭工程指的是用于给排水、排水、通气、热水、电缆等进出线的防护闭工程。 ·当道防护闭隔墙时必须预埋带有闭翼环和防护抗力片的闭穿墙短。当道闭墙时必须预埋带有闭翼环的闭穿墙短。 ·给水、压力排水、电缆电线等的闭穿墙短应按设计要求制作。应采用厚度大于3mm的钢。其焊缝应饱满、均匀、严。 ·通风的闭穿墙短应采用厚度2—3mm的钢板焊接制作其焊缝应饱满、均匀、严。 ·闭翼环应采用厚度大于3mm的钢板制作。钢板应平整其翼高宜为30—50mm。闭翼环与闭穿墙短的结合部位应满焊。 ·闭翼环应位于墙体厚度的中间并应于周围构造钢筋焊牢。闭穿墙短的轴线应与所在墙面垂直端面应平整。 ·闭穿墙短两端伸出墙面的长度应符合设计要求。当设计规定时应符合以下要求: 电缆、电线穿墙短宜为30~50mm; 给排水穿墙短应大于40mm; 通风墙短应大于100mm。 ·闭穿墙短作套时应符合以下要求: ·在套与道之间应用封材料填充实并应在口两端进展闭处理。填料长度应为径的3~5倍且不得小于100mm; ·道在套内不得有接口; ·套内径应比道外径大30~50mm。 ·闭穿墙短应在朝向核冲击波加装防护抗力片。抗力片宜采用厚度大于6mm的钢板制作。抗力片上槽口宽度应与所的线外径一样;两快抗力片的槽口必须对插。 ·当同一处有多根线需作穿墙闭处理时可在闭穿墙短两端各焊上一块闭翼环应与所在墙体的钢筋焊牢且不得露出墙面。 给水排水工程的质量控制 A、监理控制目的内容 给水排水工程是人民防空工程的一个重要分部工程。该分部工程一般包括以下七个分项工程: ·给水道安装 ·给水道附件及卫生器具给水配件安装。 ·给水附属设备安装。 ·排水道安装。 ·卫生器具安装。 ·洗消器具安装。 ·立式水泵安装。 B、有关人防工程专业要求的给排水工程的预埋和安装 ·所有人防工程围护构造、临空墙、闭墙的给排水道预埋带有闭翼环的闭穿墙短作为套。 预埋时检查预埋套材质、规格、标高、轴线位置必须按设计要求、图集施工。检查在临空墙防两个单元之间是否按施工图或、图集预埋套固定法兰与套之间必须两面满焊紧贴墙面的固定法兰与套之间焊逢必须平整放置时套与墙面必须垂直固定法兰必须垂直紧贴模板预埋时与混凝土结合部位不能油漆尤其的露出部位要涂刷防腐漆。 穿墙套内的段不得有接头穿墙与套的填充材料一般用沥青麻丝用于填料的温度>40°时应用沥青石棉绳。临空墙的在填料完成后要焊抗力挡板抗力挡板的外圆要和套的固定法兰满焊抗力挡板的内圆不得与穿墙段焊接。 ·洗消排水设计要求采用Dg80镀锌丝扣连接宜用角钢支架、U型卡固定镀锌钢不得用电焊焊接固定。预埋时要注意标高钢质堵的上平面在土建标高低5mm伸入洗消排水井的段要注意标高在建筑物下一0.25m离洗消排水井壁0.25m以上满足井盖闭合及安装阀门阀门严禁采用活接连接。 ·洗消给水闭墙必须采用φ70的穿墙套。在人防设置的阀门前段严禁采用活接连接Dg以上的道按图集制作预埋套。 ·如设计要求排水道采用防爆地漏预埋时必须注意标高上平面在土建标高以下5mm要直接预埋在混凝土内。 ·自动消防喷淋道固定吊、支架设置应合理、结实不应有晃动。成排地喷淋道、喷头及吊支架应一直线Dg50以上的道不能直接用U型卡受力要受力在角钢上宜设置龙门支架固定。支架的材质型、规格必须按设计要求施工制作、安装。吊架与喷头之间的间隔 不直小于300mm与末端喷头之间不宜大于750mm。吊架的间距不宜大于3.6m。 ·道或支吊架件在涂刷底漆前必须去除外表的灰尘、污垢、锈斑、焊渣等物涂刷应均匀颜色一致涂膜应附着结实无剥落、皱纹、气泡、针孔等缺陷。道安装后不宜涂漆部位应预先涂漆涂层应完好、无损伤、流淌等现象。 ·法兰连接的道紧固螺栓的方向应一致螺杆露出螺母部分宜为螺杆直径的1/2长短要一致。 ·进入人防工程的给水道必须在工程内侧设工作压力≥1.0Mpa的闸阀在两个防护单元进出线必须在进出两侧设工作压力≥1.0Mpa的闸阀。 ·室内消火栓应设在明显易于取用的地点栓口离地高度为1.1m,其出水方向直向下或与设置消火栓的墙面成900角消防配水立固定支架高度距地面应为1.5~1.8m但在工程或小区中高度应一致。 10、 道焊接时应根据钢的壁厚在对口处留有一定的间隙〔一般1.5~3.0mm〕并按规定坡口焊缝应平整、饱满、焊波均匀一致。焊完后立即出去渣皮、飞溅并应将焊缝外表处理干净焊缝及标志在试压前不应涂漆。镀锌钢不应采用焊接连接被破坏的镀锌外表及螺纹露出部分应做防腐处理。 C、监理程序 给水排水工程施工质量监理工作分为以下三个阶段:监理工作准备工程施工过程监理工程质量的检验评定、工程验收和资料整理。 D、监理工作准备 ·熟悉施工图和有关资料编制监理施行细那么。 监理工程师在工程开工前应熟悉有关施工图纸理解设计要求。明确工程各构成部分专业工种和工序之间的关系。参加设计交底和图纸会审。对工程特点、难点和关键部位做到心中有数。熟悉相关、、规程和有关技术资料。编制监理施行细那么。 ·工现场质量理制度建立 检查和催促施工确定或编制相应的技术建立健全的质量理体系施工质量检验制度和质量程度评定考核制度。 上海申海建立监理 上海中广核技术产业研发中心工程监理部 2021年8月- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- 中广核 地下室 人防工程 监理 实施细则
咨信网温馨提示:
1、咨信平台为文档C2C交易模式,即用户上传的文档直接被用户下载,收益归上传人(含作者)所有;本站仅是提供信息存储空间和展示预览,仅对用户上传内容的表现方式做保护处理,对上载内容不做任何修改或编辑。所展示的作品文档包括内容和图片全部来源于网络用户和作者上传投稿,我们不确定上传用户享有完全著作权,根据《信息网络传播权保护条例》,如果侵犯了您的版权、权益或隐私,请联系我们,核实后会尽快下架及时删除,并可随时和客服了解处理情况,尊重保护知识产权我们共同努力。
2、文档的总页数、文档格式和文档大小以系统显示为准(内容中显示的页数不一定正确),网站客服只以系统显示的页数、文件格式、文档大小作为仲裁依据,个别因单元格分列造成显示页码不一将协商解决,平台无法对文档的真实性、完整性、权威性、准确性、专业性及其观点立场做任何保证或承诺,下载前须认真查看,确认无误后再购买,务必慎重购买;若有违法违纪将进行移交司法处理,若涉侵权平台将进行基本处罚并下架。
3、本站所有内容均由用户上传,付费前请自行鉴别,如您付费,意味着您已接受本站规则且自行承担风险,本站不进行额外附加服务,虚拟产品一经售出概不退款(未进行购买下载可退充值款),文档一经付费(服务费)、不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
4、如你看到网页展示的文档有www.zixin.com.cn水印,是因预览和防盗链等技术需要对页面进行转换压缩成图而已,我们并不对上传的文档进行任何编辑或修改,文档下载后都不会有水印标识(原文档上传前个别存留的除外),下载后原文更清晰;试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓;PPT和DOC文档可被视为“模板”,允许上传人保留章节、目录结构的情况下删减部份的内容;PDF文档不管是原文档转换或图片扫描而得,本站不作要求视为允许,下载前自行私信或留言给上传者【xrp****65】。
5、本文档所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用;网站提供的党政主题相关内容(国旗、国徽、党徽--等)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
6、文档遇到问题,请及时私信或留言给本站上传会员【xrp****65】,需本站解决可联系【 微信客服】、【 QQ客服】,若有其他问题请点击或扫码反馈【 服务填表】;文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“【 版权申诉】”(推荐),意见反馈和侵权处理邮箱:1219186828@qq.com;也可以拔打客服电话:4008-655-100;投诉/维权电话:4009-655-100。
1、咨信平台为文档C2C交易模式,即用户上传的文档直接被用户下载,收益归上传人(含作者)所有;本站仅是提供信息存储空间和展示预览,仅对用户上传内容的表现方式做保护处理,对上载内容不做任何修改或编辑。所展示的作品文档包括内容和图片全部来源于网络用户和作者上传投稿,我们不确定上传用户享有完全著作权,根据《信息网络传播权保护条例》,如果侵犯了您的版权、权益或隐私,请联系我们,核实后会尽快下架及时删除,并可随时和客服了解处理情况,尊重保护知识产权我们共同努力。
2、文档的总页数、文档格式和文档大小以系统显示为准(内容中显示的页数不一定正确),网站客服只以系统显示的页数、文件格式、文档大小作为仲裁依据,个别因单元格分列造成显示页码不一将协商解决,平台无法对文档的真实性、完整性、权威性、准确性、专业性及其观点立场做任何保证或承诺,下载前须认真查看,确认无误后再购买,务必慎重购买;若有违法违纪将进行移交司法处理,若涉侵权平台将进行基本处罚并下架。
3、本站所有内容均由用户上传,付费前请自行鉴别,如您付费,意味着您已接受本站规则且自行承担风险,本站不进行额外附加服务,虚拟产品一经售出概不退款(未进行购买下载可退充值款),文档一经付费(服务费)、不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
4、如你看到网页展示的文档有www.zixin.com.cn水印,是因预览和防盗链等技术需要对页面进行转换压缩成图而已,我们并不对上传的文档进行任何编辑或修改,文档下载后都不会有水印标识(原文档上传前个别存留的除外),下载后原文更清晰;试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓;PPT和DOC文档可被视为“模板”,允许上传人保留章节、目录结构的情况下删减部份的内容;PDF文档不管是原文档转换或图片扫描而得,本站不作要求视为允许,下载前自行私信或留言给上传者【xrp****65】。
5、本文档所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用;网站提供的党政主题相关内容(国旗、国徽、党徽--等)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
6、文档遇到问题,请及时私信或留言给本站上传会员【xrp****65】,需本站解决可联系【 微信客服】、【 QQ客服】,若有其他问题请点击或扫码反馈【 服务填表】;文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“【 版权申诉】”(推荐),意见反馈和侵权处理邮箱:1219186828@qq.com;也可以拔打客服电话:4008-655-100;投诉/维权电话:4009-655-100。
关于本文