NFPA 54 ANSI Z223.1-2021 美国燃气规范.pdf
《NFPA 54 ANSI Z223.1-2021 美国燃气规范.pdf》由会员分享,可在线阅读,更多相关《NFPA 54 ANSI Z223.1-2021 美国燃气规范.pdf(177页珍藏版)》请在咨信网上搜索。
1、Copyright 2020 National Fire Protection Association and the American Gas Association.All Rights Reserved.NFPA 54 ANSI Z223.l-2021 National Fuel Gas Code 2021 Edition This edition ofNFPA 54/ANSI Z223.l,National Fuel Gas Code,wa5 prepared by the Technical Committee on National Fuel Gas Code.It was iss
2、ued by the Standards Council on March 15,2020,with an effective date of April 4,2020,and supersedes all previous editions.This edition of NFPA 54/ANSI Z223.l was approved as an American National Standard on April 4,2020.The ANSI designation,Z223.1-2021,was approved on April 2,2020.The NFPA designati
3、on is NFPA 54-2021.Origin and Development of NFPA 54/ANSI Z223.1 This code offers criteria for the installation and operation of gas piping and gas equipment on consumers p1emises.It is the cumulative result of years of experience of many individuals and many organizations acquainted with the instal
4、lation of gas piping and equipment designed for utilization of gaseous fuels.It is intended to promote public safety by providing requirements for the safe and satisfactory uti.lization of ga.Changes in this code can become necessary from time to time.vVhen any revision is deemed advisable,recommend
5、ations should be forwarded to the Secretary,Accredited Standards Committee Z223,400 N.Capitol St.NW,Washington,DC 20001,and the Secretary,Standa1-ds Council,National Fire Protection Association,1 Batterymarch Park,Quincy,MA 02169-7471.Prior to 1974,the following three codes covered the installation
6、of gas piping and appliances:(1)American National Standard Installation of Gas Appliances and Gas Piping,ANSI Z21.30(NFPA 54)(2)Installation of Gas Piping and Gas Equipment on lndust1ial Premises and Certain Other Premises,ANSI Z83.l(NFPA54A)(3)Fuel Gas Piping,ASME B31.2 The first edition of the cod
7、e was issued in 1974.It combined the requirements of the three predecessor documents.The American Gas Association and the National Fire Protection Association have continued co-sponsorship of the code following the first edition.The second edition of the code,incorporating pertinent portions of B31.
8、2,was issued in 1980 and 1eorganized the code to the current fonnat.Subsequent editions were issued in 1984,1988,1992,1996,1999,and 2002,respectively.The scope of the code was expanded in 1988 to include piping systems up to and including 125 psi(862 kPa).Revision highlights from subsequent editions
9、 include the following:The 2006 edition incorporated expanded steel,copper,and polyethylene pipe sizing tables.Requirements for appliance shutoff valves were revised to allow manifold systems with all shutoff valves in one location up to 50 ft(15 m)from the most remote appliance,and the chapters wer
10、e reorganized by application.The 2009 edition included allowing press-connect fittings for gas tubing systems,new 1equirements for bonding of CSST piping systems,expanded CSST sizing tables to recognize additional available sizes,new coverage of outdoor decorative appliances,and a new requirement to
11、 seal the annular space around the side wall vent penetrations.The 2012 edition included revised fuel gas piping pmging procedures that requi1e outdom-purging of piping with larger pipe sizes or higher operating pressures and allows smaller or lower operating pressure piping to be purged indoors und
12、er specific conditions.NFPA and National Fire Protection Association are registered trademarks of the National Fire Protection Association,Quincy,Massachusetts 02169.54-1 54-2 NATIONAL FUEL GAS CODE The 2015 edition revised the bonding requirements for CSST so that the bonding connection can be plac
13、ed on any metallic fitting in the piping system as long as the bonding jumper does not exceed 75 ft(22 m)in length.Overpressure protection requirements were revritten and overpressure protection is required on any system containing an appliance with a maximum inlet pressure of 14 in.w.c.(3.5 kPa)tha
14、t is supplied with gas at the point of delivery at a pressure greater than 2 psig(14 kPa).Annex G,Recommended Procedure for Safety Inspection of an Existing Appliance Installation,was expanded and revised to reflect modern appliances and test methods.In the 2018 edition,revisions to piping included
15、allowing listed arc-resistant jacket or coated CSST to use the appliances electrical grounding connector as the bonding means and recognizing stainless steel smooth wall pipe and tubing products as acceptable piping materials.The minimum allowed wall thickness of carbon and stainless steel pipe was
16、revised to Schedule 10,but joints on Schedule 10 pipe cannot be ma.de with screwed fittings.Press-connect fittings were added as an acceptable joining method for pipe.Revisions to the venting requirements included requiring listing to the appropriate UL standards for plastic venting materials,factor
17、y-built chimneys,Type Band 8.V vents,chimney lining systems,and special gas vent.Direct vent clearances to building openings for appliances with an input above 150,000 Btu(44 kW)a.re to be in accordance with the appliance manufacturers installation instructions.Finally,in Chapter 9 a requirement was
18、 added that an existing gas appliance installation be inspected for combustion air and venting code compliance when the building structure that it is installed in is modified with specific air infiltration-reducing changes.The 2021 edition includes revisions in Chapter 10 that now require appliances
19、 to be listed to and in compliance with the a.pprop1-iate ANSI/CSA appliance listing standard,thereby providing an increased level of safety.Installation requirements for unlisted appliances have been removed,and they will now have to be evaluated through the application of equivalency.A table for t
20、hrough the wall vent terminal clearances has been added to Chapter 12,along with an associated annex figure that coordinates this code with the clearances in ANSI product standards.Engineering methods a1-e now defined in Chapter 4 to provide guidance to authorities having jurisdiction on acceptable
21、engineering methods that/ill eliminate the need to approve individually all engineering methods used.Finally,electric isolation requirements for gas piping installation have been revised and reorganized to better reflect where the dielectric union is to be installed in the system and what it is prot
22、ecting.2021 Edition COMMITIEE PERSONNEL Technical Committee on National Fuel Gas Code Joint Listing of NFPA 54 and ASC Z223 Committee Frank J.Mortimer,Chair EMC Insurance Company,lA I/I Rep.Property Casualty Insurers Association of America Paul W.Cabot,Nonvoting Secretary American Gas Association,DC
23、 JM Rep.American Gas Association Dmitry Antonov,lntertek,NY RT/AR-TL Eric Adiart,Hearth,Patio&Barbecue Association,VA M Thomas Andrews,Michigan Technical Education Center,Ml SE/SE David Berningt,Product Design Engineering,SC M JonathanBrania,ULLLC,NC RT/AR-TL James P.Brewer,Magic Sweep Corporation,V
24、A IM/1-M Rep.National Chimney Sweep Guild Chris Dale Byers,Piedmont Natural Gas,SC U/ES Thomas R.Crane,Crane Engineering,MN SE/SE Gerald G.Davis*,Williams Meter Company,MD IM Mike Deegan,Clearwater Gas System,FL U/ES Rep.American Public Gas Association Mark Fasel,Viega LLC,IN M/M Alberto Jose Fossa*
25、,NEWEN Creative Engineering,Brazil SE Rep.NFPA Latin American Section Richard L.Gilbert*,Texas Propane Gas Association,TX IM Enrique Trejo Gonzalez,International Association of Plumbing&Mechanical Officials(lAPMO),CA E/EA Rep.International Association of Pltm1bing&Mechanical Officials Mike Gorham,No
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NFPA 54 ANSI Z223.1-2021 美国燃气规范 Z223 2021 美国 燃气 规范
1、咨信平台为文档C2C交易模式,即用户上传的文档直接被用户下载,收益归上传人(含作者)所有;本站仅是提供信息存储空间和展示预览,仅对用户上传内容的表现方式做保护处理,对上载内容不做任何修改或编辑。所展示的作品文档包括内容和图片全部来源于网络用户和作者上传投稿,我们不确定上传用户享有完全著作权,根据《信息网络传播权保护条例》,如果侵犯了您的版权、权益或隐私,请联系我们,核实后会尽快下架及时删除,并可随时和客服了解处理情况,尊重保护知识产权我们共同努力。
2、文档的总页数、文档格式和文档大小以系统显示为准(内容中显示的页数不一定正确),网站客服只以系统显示的页数、文件格式、文档大小作为仲裁依据,个别因单元格分列造成显示页码不一将协商解决,平台无法对文档的真实性、完整性、权威性、准确性、专业性及其观点立场做任何保证或承诺,下载前须认真查看,确认无误后再购买,务必慎重购买;若有违法违纪将进行移交司法处理,若涉侵权平台将进行基本处罚并下架。
3、本站所有内容均由用户上传,付费前请自行鉴别,如您付费,意味着您已接受本站规则且自行承担风险,本站不进行额外附加服务,虚拟产品一经售出概不退款(未进行购买下载可退充值款),文档一经付费(服务费)、不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
4、如你看到网页展示的文档有www.zixin.com.cn水印,是因预览和防盗链等技术需要对页面进行转换压缩成图而已,我们并不对上传的文档进行任何编辑或修改,文档下载后都不会有水印标识(原文档上传前个别存留的除外),下载后原文更清晰;试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓;PPT和DOC文档可被视为“模板”,允许上传人保留章节、目录结构的情况下删减部份的内容;PDF文档不管是原文档转换或图片扫描而得,本站不作要求视为允许,下载前自行私信或留言给上传者【wei****ing】。
5、本文档所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用;网站提供的党政主题相关内容(国旗、国徽、党徽--等)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
6、文档遇到问题,请及时私信或留言给本站上传会员【wei****ing】,需本站解决可联系【 微信客服】、【 QQ客服】,若有其他问题请点击或扫码反馈【 服务填表】;文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“【 版权申诉】”(推荐),意见反馈和侵权处理邮箱:1219186828@qq.com;也可以拔打客服电话:4008-655-100;投诉/维权电话:4009-655-100。