1、目 录Directory一、施工地点:Job location1二、参照标准: Basis of compiling1三、材料标准:Material streamlined specification1(一)钢管:Steel pipe1(二)扣件:Fastener1(三)脚手板:Scaffold board2(四)安全网:Protecting net2四、施工工艺:Construction technique2(一)施工准备:Preparations for construction2(二)脚手架搭设的要求:Requirement of scaffold3A、立杆构造要求:Vertical4B
2、、纵向水平杆的构造要求:Longitudinal horizontal bracing4C、横向水平杆的构造要求:Transverse horizontal bracing5D、脚手板的设置:Scaffold board laying5E、剪刀撑:X-bracing6F、扣件:Fastener6(三)脚手架的使用:Requirement of use the scaffold6(四)脚手架的拆除:Demolition the scaffold7五、注意事项:Notice proceeding7 一、施工地点:Job location*化工区工业气体二期管道设备保温工程* caojing HYC
3、O1 STEP-2 insulation project 二、参照标准: Basis of compilingJGJ130-2001 建筑施工扣件式钢管脚手架安全技术规范Steel pipe scaffold safety code of building construction with the fastener三、材料标准:Material streamlined specification(一)钢管:Steel pipe1、脚手架钢管采用外径48mm,壁厚3.5mm,横向水平杆2200mm,其他杆6500mm,每根钢管不应大于25kg。2、钢管表面应平直光滑,不应有裂缝、结疤、分层、错
4、位、硬弯、毛刺、压痕和深的划道。3、钢管的外径、壁厚、端面等的偏差,应分别符合建筑施工扣件式钢管脚手架安全技术规范(JGJ130-2001)的有关规定。1.The external diameter of the steel pipe is 48mm, and thickness of pipe wall is 3.5mm. Transverse horizontal bracing shall be less than 2200mm,others less than 6500mm,and every steel pipe shall be less than 25kg.2.The surfa
5、ce of the steel pipe shall be smoothness, and has not the crack, dogs ear, delaminating, burr and deep nick etc.3.The deviation of the steel pipe, as the external diameter, thickness of pipe wall, port etc, shall be accord the code Steel pipe scaffold safety code of building construction with the fa
6、stener(二)扣件:Fastener1、扣件采用48型。扣件的类型包括:直角扣件、旋转扣件、对接扣件、防滑扣件。2、脚手架采用的扣件,其材质应符合国家现行标准。1.Fastener adopt the type of 48,and the types include the right-angle, circumgyrate, butt joint, and slip-resistance.2.The fastener of the scaffold shall be accord the GB code.(三)脚手板:Scaffold board1、脚手板采用木质,每块质量不宜大于30k
7、g。2、木脚手板应采用杉木或松木制作,其材质应符合国家现行标准。3、脚手板的宽度不宜小于200mm,厚度不应小于50mm,两端应各设直径4mm的镀锌铁丝绑扎两道。1.Every scaffolds quality shall be less than 30kg.2.Scaffold board shall be make of the fir or deal, and accord the GB code.3.The width of the scaffold board shall be over 200mm and thickness over 50mm. On the ends with
8、 the 4mm galvanized wire fixing the board.(四)安全网:Protecting net在脚手架施工操作面和护栏四周围上防护网。It shall be laying safety netting on the operating platform and protecting fence.四、施工工艺:Construction technique(一)施工准备:Preparations for construction1、工程负责人应按施工组织设计中有关脚手架的要求,向架设和使用人员进行技术交底。2、应对所有进场材料按规范进行验收,不合格产品不得使用。3、
9、经检验合格的构配件应按品种、规格分类、堆放整齐、平稳,堆放场地不得有积水。4、当脚手架基础下有设备基础、管沟时,必须采取加固措施。1.The project manager shall be show the regulations for technical operation on the operation worker, about scaffold in this scheme.2.All the material must be check and acceptance, and no qualification no use.3.The qualification materia
10、l shall be stack-up regularity and firmness. The place shall be no water.4.When it has equipment foundation, pipe duct under the base of scaffold, it must to be consolidation.(二)脚手架搭设的要求:Requirement of scaffold1、所搭设的脚手架要坚固、稳定,保证在施工期内及各种载荷和气候条件下不产生变形,不倾斜、不摇晃,安全可靠。2、根据搭设空间,选用适宜的脚手架钢管长度。必须有足够的空间,满足操作、材
11、料堆放及行人的要求。3、脚手架的搭设宽度根据构造要求不能小于1-1.3m,作业层大横杆间隔La/2m,小横杆间隔不能大于纵距的1/2,立杆横距不能大于1-1.3m,立杆纵距不能大于1.5-2.0m。4、K201-K202整体脚手架重大约16T,搭设面长10.3米宽4.6米高度30米,搭设时层面和作业平台连接.支撑以减少整体负荷, 施工人员上下可利用原有设施,作业平台和施工平面须使用梯子上下。1.The scaffold must be firmness, steadiness. During the useful time, it must be no deformation, no incl
12、ination, no sway and safety on the kind of load and climate.2.The pipe of the scaffold must be select the suitable length by the building space, and the space must be enough to suitable for operate, material stack-up and passage.3.The width of the scaffold shall be more than 1-1.3m. In the operating
13、 lay, the big traverse bar shall be distance La/2m, and the small traverse bar shall be less than 1/2 of longitudinal distance. The traverse distance of vertical shall be less than 1-1.3m, and longitudinal less than 1.5-2.0m.4.The scaffold weight of the equipment K201-K202 is about 16T,length about
14、10.3m, width 4.6m, and height about 30m. When its building, the operating lay join the platform to reduce the load. The worker may be use the device, when they up and down, but on operating lay must be use the ladder.A、立杆构造要求:Vertical1、脚手架必须调协纵、横向扫地杆。纵向扫地杆应用直角扣件固定在距底座上皮不大于200mm处的立杆上,横向扫地杆应用直角扣件固定在紧靠
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- 脚手架 搭设 施工 方案 中英文 教学 文案
1、咨信平台为文档C2C交易模式,即用户上传的文档直接被用户下载,收益归上传人(含作者)所有;本站仅是提供信息存储空间和展示预览,仅对用户上传内容的表现方式做保护处理,对上载内容不做任何修改或编辑。所展示的作品文档包括内容和图片全部来源于网络用户和作者上传投稿,我们不确定上传用户享有完全著作权,根据《信息网络传播权保护条例》,如果侵犯了您的版权、权益或隐私,请联系我们,核实后会尽快下架及时删除,并可随时和客服了解处理情况,尊重保护知识产权我们共同努力。
2、文档的总页数、文档格式和文档大小以系统显示为准(内容中显示的页数不一定正确),网站客服只以系统显示的页数、文件格式、文档大小作为仲裁依据,个别因单元格分列造成显示页码不一将协商解决,平台无法对文档的真实性、完整性、权威性、准确性、专业性及其观点立场做任何保证或承诺,下载前须认真查看,确认无误后再购买,务必慎重购买;若有违法违纪将进行移交司法处理,若涉侵权平台将进行基本处罚并下架。
3、本站所有内容均由用户上传,付费前请自行鉴别,如您付费,意味着您已接受本站规则且自行承担风险,本站不进行额外附加服务,虚拟产品一经售出概不退款(未进行购买下载可退充值款),文档一经付费(服务费)、不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
4、如你看到网页展示的文档有www.zixin.com.cn水印,是因预览和防盗链等技术需要对页面进行转换压缩成图而已,我们并不对上传的文档进行任何编辑或修改,文档下载后都不会有水印标识(原文档上传前个别存留的除外),下载后原文更清晰;试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓;PPT和DOC文档可被视为“模板”,允许上传人保留章节、目录结构的情况下删减部份的内容;PDF文档不管是原文档转换或图片扫描而得,本站不作要求视为允许,下载前自行私信或留言给上传者【a199****6536】。
5、本文档所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用;网站提供的党政主题相关内容(国旗、国徽、党徽--等)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
6、文档遇到问题,请及时私信或留言给本站上传会员【a199****6536】,需本站解决可联系【 微信客服】、【 QQ客服】,若有其他问题请点击或扫码反馈【 服务填表】;文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“【 版权申诉】”(推荐),意见反馈和侵权处理邮箱:1219186828@qq.com;也可以拔打客服电话:4008-655-100;投诉/维权电话:4009-655-100。