蒂森控制板操作器说明.doc
《蒂森控制板操作器说明.doc》由会员分享,可在线阅读,更多相关《蒂森控制板操作器说明.doc(39页珍藏版)》请在咨信网上搜索。
1、THYSSENAUFZUGSWERKEOperating Instructions Diagnostic Unit IFunctions6510 046 Type Type No.DIAGNOSTIC UNIT ILK sensorRun: IS/RS 2)UP direction with ISDOWN direction with ISProgram selector wheelLN sensorW/W1 contactorWO/WU SchtzPulsesCheck-back SR moduleSafety circuitEKHKTKKTSeven-segment-function di
2、splayflashing1)Start/Stop buttonFunction 01 00Display of error stackas per: 05.00显示故障堆栈Example:Error ExplanationWeighting BW14 03 AAjob-specific error messag任务特性故障信息Nemergency stop 紧急停梯 XXlanding 楼层Sstopping 停止 YYundefined 未定义Mspontaneous message 自发信息 NNexplanations from page 21 解释见21页Blift blocked
3、电梯被锁定 ZZNumber of marking flag 标志编号 .Boperation phase运行阶段Significance:Frequency levels of error:含义:故障频繁度Level 1 infrequent 1度不频繁发生 Error code number 故障代码Level10 frequent 10度频繁发生ErrorError descriptionCauses, remedy or instructionsBW01 XXInterlock contact RK or RKD is jamming in landing XX. 门锁触点RK或RKD
4、在XX楼层处卡住/在XX层检查门锁触点或门的机械部件。在任务特性程序中必须将门的型号编程输入Check interlock contact or mechanical parts of door in landing XX.A correct door type must be programmed in the job-specific program.602 01Calls inhibited via monitoring 召唤因监控作用被禁止An 8-kbyte RAM is required in CPU. CPU 中需要一块8-KBYTE RAM102 02Quasi ZSE in
5、lift-specific program released, but Siemens CPU still used.在电梯特性程序中QUASI的ZSE开关被删掉,但在SIEMENS的CPU中仍使用Use Thyssen CPU with battery-backed RAM chip (storage of position in the event of power failure or if HS is switched off).用THYSSEN的CPU后备电池的RAM芯片(停电或HS断开时存储位置信息)102 03TCM control TCM控制8 k-RAM not recogn
6、ized; F8 00 will follow 8K-RAM未识别;随之以F800102 04TCM control TCM控制8 k-EPROM not recognized; F8 00 will follow8K-EPRAM未识别;随之以F800102 80Undefined or wrong operation phase未定义或错误的运行阶段103 01No provision has been madefor disconnect landing in lift-specific program. 在电梯特性程序中没有编入关梯楼层Disconnect landing not pro
7、grammed (check data sheet) or incorrect order number on lift-specific EPROM. 关梯楼层未编程(检查数据表)或电梯特性EPROM中的定单号不正确103 02No provision has been made for parking landing in lift-specific program. 在电梯特性程序中没有编入停泊楼层Parking landing not programmed, etc., same as for error 03 01.停泊楼层未编程03 03No provision has been
8、made for firemans landing in lift specific program. 在电梯特性程序中没有编入消防员楼层Firemans landing not programmed, etc., same as for error 03 01. 消防员楼层未编程04 NNTCI: error caused by solenoid switch ZSE. 由磁开关ZSE引起的故障/CPU检查是否有一个以上ZSE开关动作,如果是则停梯并故障连续储存4次/检查ZSE开关/参考来自21页的说明TCI: CPU checks whether more than one ZSE swi
9、tch is actuated. If so, the lift will be stopped and error 04 NN stored four times in succession.Check ZSE solenoid switch. SM304 XXTCM: error caused by soldenoid switch ZSE.由磁开关ZSE引起的故障/CPU检查是否有一个以上ZSE开关动作,所有ZSE动作的楼层XX都会显示/检查ZSE开关/例如消防员梯CPU checks whether more than one ZSE switch is actuated. All l
10、andings XX with ZSE actuated will be displayed. Check ZSE solenoid switch, for example firemans lift.05 YYIncorrect computer request by group (circuit board MG defective or fault in group connection).来自群控的不正确计算机请求(MG板损坏或群控接线错误)/TCI:检查MG板或群控接线/TCM:检查群控总线(MZ1板)软件故障:核实工作程序版本和次级标志YY并通知蒂森公司VTS部TCI: Check
11、 circuit board MG or group connection (round cable or flat cable).TCM: check group bus (MZ1 circuit board)Software error: identify work program version and subidentification (YY) and inform Thyssen Aufzugswerke department VTS !2Error of TCM lift controls TCM电梯控制装置的故障05 XXSpecial program error messag
12、es from TCM group. Will be output after errors indicated below !来自TCM群控的特殊程序故障信息。在指示出下列故障之后会被输出Inform TU or VTS as soon as this error occurs.XX = Data for detailed error description一旦发生此故障须通知TU或VTS部XX=故障详细数据-05 42Number of lifts of group and/or number of landings of group unacceptable.群内电梯数和/或群控楼层数不
13、能接受-05 53Run telegram in incorrect group phase; 05 XX follows不正确的群控阶段中的运行电报,随之以XXPoor group connection of lift XX XX = lift numberXX电梯的群控接线不良,XX=电梯号-05 A0Group protocol incompatible群控协议不兼容Same program version for all MZ1 circuit boards of the group. 群内所有的MZ1版本程序相同-05 A8Group protocol and group contr
14、ol computer are not compatible群控协议和群控计算机不兼容Check program version of MZ1 circuit board and group control computer 检查MZ1板的程序版本和群控计算机Error of TCM with destination selection contro (DCS)带目的选择控制(DCS)的TCM中的故障05 b0DCS reset, : 05 XX will followZES = destination entry terminalDCS复位随之以05XXZSE=目的的输入端ZES alway
15、s performs. Check voltage supply and CAN connection to respective ZSE.XX = concerned landingZSE一直作用;检查电源和去相应ZSE的CAN接线XX=相关楼层-05 b1Unexpected response from DCS: Hallo (= initialization program: 05 XX followsXX = concerned landing XX=相关楼层来自DCS的不应有的响应HALLO(初始化程序)-05 b2DCS send unexpected ready message
16、(= initialization terminated); 05 XX will followXX = concerned landing XX=相关楼层 /DCS送出不应有的就绪信息(初始化终止)随之XX05-05 b3DCS initialization time-out, table start: 05 XX will followDCS初始化时限到,表尾随之05XXXX=相关楼层Failure to initialize destination selection control DSC. Check voltage supply and CAN connection to resp
17、ective ZSE.XX = concerned landing/未能开始目的的选择控制DCS检查电源和去 相应的ZSE的CAN接线-05 b4DSC initialization time-out, table endDCS初始化时限到,表尾-05 b5DSC-life-time-out; 05 XX will followDCS寿命时限到。随之05XX/没有周期响应来自DSC.检查电源和去 相应的ZSE的CAN接线No cyclical response from DSC. Check voltage supply and CAN connection to respective ZSE
18、.XX = concerned landing XX=相关楼层-05 C0Special run-RESET 特殊运行复位RESETdue to timeout 因时限到而复位-General errors 普通故障06 XXEmergency stop after 3 unsuccessful locking attempts in landing XX. 在XX楼层处门锁动作3次失败后紧急停梯检查XX楼层处门锁触点或门的机械部件。见21页说明M207 01TSO故障.主门:发出命令后30秒内TSO开关未动作.CPU于是模拟TSO信号,因此当正常的等待时间到达后门就可以再次关闭TSO开关损坏
19、或调整的不对。在有轿门锁装置的电梯中轿门未锁的信息丢失.如果TSO命令没有执行时,也可能是门控制器造成的故障307 02TSO error main door (also see 0b 04)TSO故障.主门(也见OB04)虽然TK(门锁触点)接通,但TSO仍发出轿箱主门开信号.造成复位N108 01TSOD error rear door TSOD故障.后门/ TSO开关损坏或调整的不对/见0701TSOD switch defective or incorrectly adjusted (same as error 07 01). 108 02TSOD errorrear door TSO
20、D故障.后门/虽然TK(门锁触点)接通TSOD仍发出轿箱主门开信号TSOD signals car rear door open, although TK TK (door contact) is closed.N309 NNBlocking 4 min: car is in a landing and fails to start within 4 min. although commands or calls are present.轿箱在某层锁定大于4分钟虽有命令或召唤,但在4分钟内不能启动问题在再开门装置;见功能0500,OD列.如果轿箱下溜或是限速器轮粘滞,则在液压梯带防爬行装置的限
21、速器上的安全开关可能跳脱(解释见21页)M30A 2FSlack rope绳索松弛0A 30Strop outside doorzone吊索在门区之外0A 31Car door not closed轿门未关0A 32Landing door not locked厅门未关0A 33Oiltemperature over 70C油温超过70度0A 34Oil level monitoring油位监控0A 46Maintenance switch ON检修开关ON0A 47Maintenance switch OFF检修开关OFF0A AA0A XXJob-specific errorTeach-i
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- 控制板 操作 说明
1、咨信平台为文档C2C交易模式,即用户上传的文档直接被用户下载,收益归上传人(含作者)所有;本站仅是提供信息存储空间和展示预览,仅对用户上传内容的表现方式做保护处理,对上载内容不做任何修改或编辑。所展示的作品文档包括内容和图片全部来源于网络用户和作者上传投稿,我们不确定上传用户享有完全著作权,根据《信息网络传播权保护条例》,如果侵犯了您的版权、权益或隐私,请联系我们,核实后会尽快下架及时删除,并可随时和客服了解处理情况,尊重保护知识产权我们共同努力。
2、文档的总页数、文档格式和文档大小以系统显示为准(内容中显示的页数不一定正确),网站客服只以系统显示的页数、文件格式、文档大小作为仲裁依据,平台无法对文档的真实性、完整性、权威性、准确性、专业性及其观点立场做任何保证或承诺,下载前须认真查看,确认无误后再购买,务必慎重购买;若有违法违纪将进行移交司法处理,若涉侵权平台将进行基本处罚并下架。
3、本站所有内容均由用户上传,付费前请自行鉴别,如您付费,意味着您已接受本站规则且自行承担风险,本站不进行额外附加服务,虚拟产品一经售出概不退款(未进行购买下载可退充值款),文档一经付费(服务费)、不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
4、如你看到网页展示的文档有www.zixin.com.cn水印,是因预览和防盗链等技术需要对页面进行转换压缩成图而已,我们并不对上传的文档进行任何编辑或修改,文档下载后都不会有水印标识(原文档上传前个别存留的除外),下载后原文更清晰;试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓;PPT和DOC文档可被视为“模板”,允许上传人保留章节、目录结构的情况下删减部份的内容;PDF文档不管是原文档转换或图片扫描而得,本站不作要求视为允许,下载前自行私信或留言给上传者【精***】。
5、本文档所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用;网站提供的党政主题相关内容(国旗、国徽、党徽--等)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
6、文档遇到问题,请及时私信或留言给本站上传会员【精***】,需本站解决可联系【 微信客服】、【 QQ客服】,若有其他问题请点击或扫码反馈【 服务填表】;文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“【 版权申诉】”(推荐),意见反馈和侵权处理邮箱:1219186828@qq.com;也可以拔打客服电话:4008-655-100;投诉/维权电话:4009-655-100。